Process Data set: EJ Fabricated Steel with Concrete Infill Access Cover (DE) (en) en

Key Data Set Information
Location IE
Geographical representativeness description IE
Reference year 2024
Name
EJ Fabricated Steel with Concrete Infill Access Cover (DE)
Use advice for data set This LCA covers the Product (A1-A3), End of Life (C1-C4), and benefits and loads beyond the system boundary (D)
Technical purpose of product or process EJ steel fabricated lift assist access cover with concrete infill is designed to give the operator easy access to their assets. The lift assist covers are designed to have a maximum lifting effort of 25kg meaning they can be opened through a single person lift. All units are manufactured to order at EJ Boppard, Germany production facility. They can be manufactured to bespoke sizes and configurations ensuring the customers’ full needs are met. Configurations include Single, Twins & Multiple units. Size of the representative product for LCA is 800x800 mm For more information: https://www.igbc.ie/wp-content/uploads/2024/06/EPDIE-23-124-Fabricated-Steel-with-Concrete-DE-EJ-20290613.pdf The manufacturing process for fabricated steel access covers begins with the design of the access cover based on the specific requirements and configuration according to EJ client's needs. Then, steel sheets are cut into desired size and shape for the access cover. This may involve using cutting methods such as plasma or cutting saw. The cut steel pieces are then formed into the required shape through bending. This is done using presses to achieve precise angles and contours. The waste generated from the cutting process are off cuts which are collected in a scrap metal collection skip. This skip is collected by the waste collection service supplier and transported via road to a local scrap metal recycling facility. The bent steel components are assembled and welded to form the structure of the access cover. Welding ensures that the pieces are securely joined and provides structural integrity. The method used for welding is gas welding using blended gases as a fuel. The access covers undergo surface treatment to enhance its corrosion resistance and durability. This is done by means of hot-dip galvanizing, which provides a protective zinc coating. The galvanization of the access cover is done externally so the access covers are transported to a facility via a third party. Once returned to EJ manufacturing site, various features are added to the access covers as needed, such as handles, locking mechanisms, or lifting points. The completed access covers then undergo final quality control checks before being packaged for transportation and delivered. The packaging used for the access covers is a wooden pallet and banding to strap the access covers securely
General comment on data set The dataset is representative for the production processes used in 2023. The data Quality Level, according to Table E.1 of EN15804+A2, Annex E, is as follows: • Time Representativeness is considered to be Very Good • Geographical Representativeness is considered to be Good • Technical Representativeness is considered to be Good Allocation of energies, electricity types and amounts to the various manufacturing processes is based on mass The cut-off criteria of section 6.3.6 of EN15804+A2 have been followed.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2024
Technological representativeness
Technology description including background system More technical data: https://www.igbc.ie/wp-content/uploads/2024/06/EPDIE-23-124-Fabricated-Steel-with-Concrete-DE-EJ-20290613.pdf

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Use of renewable primary energy (PERE)
Input
  • 1.677
  • 0.0026
  • 0.05669
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00206
  • 0.00984
  • 0
  • -0.6299
Use of renewable primary energy resources used as raw materials (PERM)
Input
  • 0
  • 0
  • 0.02659
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Total use of renewable primary energy resource (PERT)
Input
  • 1.677
  • 0.0026
  • 0.08328
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00206
  • 0.00984
  • 0
  • -0.6299
Use of non renewable primary energy (PENRE)
Input
  • 13.42
  • 0.1521
  • 14.33
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1207
  • 0.6286
  • 0
  • -5.719
Use of non renewable primary energy resources used as raw materials (PENRM)
Input
  • 0.3384
  • 0.01443
  • 0.556
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01145
  • 0
  • 0
  • -0.08059
Total use of non renewable primary energy resource (PENRT)
Input
  • 13.76
  • 0.1665
  • 14.89
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1322
  • 0.6286
  • 0
  • -5.799
Use of secondary material (SM)
Input
  • 0.191
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.284
Use of renewable secondary fuels (RSF)
Input
  • 0.01469
  • 0.00004922
  • 0.0034
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003908
  • 0
  • 0
  • -0.00442
Use of non renewable secondary fuels (NRSF)
Input
  • 0.04806
  • 0.00009679
  • 0.00822
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00007684
  • 0
  • 0
  • -0.01067
Use of net fresh water (FW)
Input
  • 0.0034
  • 0.00002011
  • 0.00352
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001596
  • 0.00017
  • 0
  • -0.00348
Hazardous waste disposed (HWD)
Output
  • 0.5507
  • 0.00016
  • 0.00387
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00012
  • 0.000001515
  • 0
  • -0.2273
Non hazardous waste dispose (NHWD)
Output
  • 0.1224
  • 0.00806
  • 0.01395
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0064
  • 0.6152
  • 0
  • -0.02864
Radioactive waste disposed (RWD)
Output
  • 0.00001885
  • 5.434E-8
  • 0.00002042
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.314E-8
  • 0.00000419
  • 0
  • -0.000005441
Components for re-use (CRU)
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Materials for recycling (MFR)
Output
  • 0.138
  • 0.00017
  • 0.00649
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.09133
Materials for energy recovery (MER)
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Exported electrical energy (EEE)
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Exported thermal energy (EET)
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 13.76
  • 0.1665
  • 14.89
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1322
  • 0.6285
  • 0
  • -5.799
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00001268
  • 3.893E-8
  • 0.000001298
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.091E-8
  • 4.593E-8
  • 0
  • -0.000005113
Acidification potential, Accumulated Exceedance (AP)
  • 0.00566
  • 0.00002543
  • 0.00091
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002019
  • 0.00041
  • 0
  • -0.00225
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.074E-8
  • 2.53E-10
  • 4.156E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.01E-10
  • 9.081E-9
  • 0
  • -1.085E-8
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00056
  • 8.27E-7
  • 0.00014
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.565E-7
  • 0.000003209
  • 0
  • -0.00029
Eutrophication potential - marine (EP-marine)
  • 0.00123
  • 0.000006417
  • 0.00024
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005094
  • 0.00017
  • 0
  • -0.00043
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01253
  • 0.0000652
  • 0.00237
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005176
  • 0.00189
  • 0
  • -0.00459
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.01033
  • 0.00001031
  • 0.00013
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000008183
  • 0.0000557
  • 0
  • -0.00111
Global Warming Potential - fossil fuels (GWP-fossil)
  • 1.214
  • 0.01164
  • 0.3934
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00924
  • 0.041
  • 0
  • -0.5631
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.00097
  • 0.000005744
  • 0.00008275
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00000456
  • 0.00002195
  • 0
  • -0.00026
Global Warming Potential - total (GWP-total)
  • 1.226
  • 0.01165
  • 0.3936
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00925
  • 0.04108
  • 0
  • -0.5645
Global warming potential except emissions and uptake of biogenic carbon (GWP-IOBC/GHG)
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
Photochemical Ozone Creation Potential (POCP)
  • 0.00553
  • 0.00003948
  • 0.00118
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003135
  • 0.00052
  • 0
  • -0.00242
Water (user) deprivation potential (WDP)
  • -1.713
  • 0.00083
  • 0.05912
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00066
  • 0.00255
  • 0
  • -0.1667

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 6.378
  • 0.08171
  • 1.076
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.06487
  • 0.1726
  • 0
  • -1.95
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 8.883E-9
  • 5E-12
  • 1.02E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4E-12
  • 1.4E-11
  • 0
  • -3.746E-9
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.645E-8
  • 1.18E-10
  • 3.772E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9.4E-11
  • 1.29E-10
  • 0
  • -6.902E-9
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.07473
  • 0.00022
  • 0.0678
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00018
  • 0.00332
  • 0
  • -0.02155
Potential Soil quality index (SQP) 2
  • 4.648
  • 0.09988
  • 0.5026
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07929
  • 0.3223
  • 0
  • -1.904
Potential incidence of disease due to PM emissions (PM) 2
  • 1.005E-7
  • 8.67E-10
  • 4.05E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.88E-10
  • 1.81E-8
  • 0
  • -3.758E-8